Software Aplikasi USB 4 Relay (VB.net) Jual Modul Driver USB 4 Relay Canggih Murah. Tombol ON-OFF masing-masing Relay. Tagged: driver usb4rel, interfacing arduino dengan VB.net, komunikasi serial mikrokontroller dengan VB.net, modul usb 4 relay. Dec 18, 2017 Salam Innovator. Berjumpa lagi dengan Elmechtechnology.com pada kesempatan kali ini kita akan memberikan tutorial bagaimana cara membuat interface antara arduino dan visual basic melalui komunikasi serial. Banyak hal yang akan kalian dapat jika.
I have an issue with reading data from a serial port, and that data comes from an arduino that periodically (1 or 2 times a second) sends the status of what it's doing. Using Atmel studio or Arduino IDE to read the serial port, everything works fine, but I'm writing a monitoring program in VB.net 2010 and then things start to go to heck.I open my port (115200 baud) and have an event handler for the 'Datareceived' event, in this event, I have a stringbuilder which appends the output of Serial.Readline and updates a textbox with it.Now here's the problem. It only seems to read about 4-6 lines (20 bytes each), and holds up the processing on the arduino side. I've played with buffer sizes, transfer speeds (going down to 9600 didn't help, it just read less lines, and higher transfer speeds (230400) didn't change anything.
Played with the buffer length, handshakes. You name it.Here is an example of what I should be getting once per secondSample = 885 Time = 885008 RPM.Value = 0.00 RPM.Slope = 0.00 TPS.Value= 5.05 TPS.Slope = 25.25 MAP.Value = 20.58 MAP.Slope = 6.02 EGP.Value = 20.58 EGP.Slope = 3.01 TSS.Value = 0.00 TSS.Slope = 0.00 BPS.Value = 171.18 POT = 25 AUX = 25 Base Position = 80 DPR comp = 0 TPS slope comp = 74 Aux Compensation = 75 All Compensation = 149 Normal Mode =80 Overboost comp = 0 Limited Position = 229(Sorry, linebreaks didn't seem to want to work. You get the idea though)What is funny is that I'm not missing any data, my few lines of data I get come in at the frequency I should be getting all of them at.Somehow the port isn't keeping up, even though my event handler really isn't doing a whole lot. I've tried just dumping the raw serial data to the debug window, it didn't change anything. You would think that if it was a problem with the function being too demanding, I would get more or less data depending on how much I had to doCurrently working on a new idea.
Doing the parsing of the variables/values on a timer tick event (250 ms interval), and just adding each new line to a queue. It should speed things up. Instead of using the blocking ReadLine try using ReadExisting. You'll have to detect newlines and extract messages manually.
Private Sub SerPortDataReceived(sender As Object, e As IO.Ports.SerialDataReceivedEventArgs) Handles SerPort.DataReceivedStatic sb As New System.Text.StringBuildersb.Append(SerPort.ReadExisting)If sb.ToString.Contains(SerPort.NewLine) Then'the stringbuilder contains at least one message'that ends in a newlineEnd IfEnd SubThere are other(better) ways to do this, but this should help you.